Fire Retardant CAT5e U/UTP SWB Armoured Data Cables
FTX-CAT5e U/UTP4P24 swb
APPLICATION
Cat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz.
In addition, these cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing
additional mechanically protection still maintaining the flexibility of the cable.
STANDARDS
Basic design adapted to EN50173
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test)
|
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
|
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)
|
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
|
Halogen Free
|
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;
CEI 20-37/2-1 ; BS 6425-1*
|
No Corrosive Gas Emission
|
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;
CEI 20-37/2-2 ; BS 6425-2*
|
Minimum Smoke Emission
|
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
|
No Toxic gases
|
NES 02-713; NF C 20-454
|
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
60V
CABLE CONSTRUCTION
Conductors: 24AWG solid bare copper.
Insulation: HDPE.
Twinning: Two coloured insulated conductors twisted together to form a pair.
Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.
Armouring:
swb: Steel Wire Braid
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type
SW2-SW4 as per BS 7655:section 2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance,
anti rodent and anti termite properties can be offered as option.
Physical AND THERMAL PROPERTIES
Temperature range: -30°C ~ +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter
Electrical Properties
AWG
|
|
24
|
Nominal Conductor Diameter
|
mm
|
0.5/0.51
|
Maximum DC Resistant@20°C
|
Ω/100m
|
9.38
|
Maximum DCR Unbalance
|
%
|
5
|
Maximum Mutual Capacitance
|
pF/m
|
55.8
|
Maximum Capacitance Unbalance
|
pF/100m
|
330
|
Characteristic Impedance@1-100MHz
|
Ω
|
100+/-15
|
Maximum Propagation Delay Skew
|
ns/100m
|
45
|
Transmission Properties
FREQ
MHz
|
Maximum Attenuation
dB/100m
|
Minimum NEXT
dB
|
Minimum PSNEXT
dB
|
Minimum ELFEXT
dB/100m
|
Minimum PSELFEXT
dB/100m
|
Minimum RL
dB
|
0.772
|
1.8
|
67.0
|
64.0
|
66.0
|
63.0
|
—
|
1
|
2.0
|
65.3
|
62.3
|
63.8
|
60.8
|
20.0
|
4
|
4.1
|
56.3
|
53.3
|
51.7
|
48.7
|
23.0
|
8
|
5.8
|
51.8
|
48.8
|
45.7
|
42.7
|
24.5
|
10
|
6.5
|
50.3
|
47.3
|
43.8
|
40.8
|
25.0
|
16
|
8.2
|
47.3
|
44.3
|
39.7
|
36.7
|
25.0
|
20
|
9.3
|
45.8
|
42.8
|
37.7
|
34.7
|
25.0
|
25
|
10.4
|
44.3
|
41.3
|
35.8
|
32.8
|
24.3
|
31.25
|
11.7
|
42.9
|
39.9
|
33.9
|
30.9
|
23.6
|
62.5
|
17.0
|
38.4
|
35.4
|
27.8
|
24.8
|
21.5
|
100
|
22.0
|
35.3
|
32.3
|
23.8
|
20.8
|
20.1
|
CONSTRUCTION PARAMETERS
Cable Code
|
Construction
No. of elements×No. of cores in element×Conductor Diameter
|
Nominal Insulation Thickness
|
Nominal
Inner
Sheath
Thickness
|
Nominal
Outer
Sheath
Thickness
|
Nominal Overall Diameter
|
Nominal Weight
|
|
mm
|
mm
|
mm
|
mm
|
mm
|
kg/km
|
FTX-CAT5e U/UTP SWB
|
4×2×0.5/0.51
|
0.2
|
0.6
|
1.0
|
7.68
|
93
|